Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathnec-pbx-client.js
150 lines (137 loc) · 4.86 KB
/
nec-pbx-client.js
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
/*
Module to conenct to buffer and respond to SMDR messages.
*/
/*
This program is free software. It comes without any warranty, and is offered “as-is”, without warranty. The software user accepts all liability for damages resulting in the use of this software.
All trademarks are the property of their respective owners.
No agreement has been made between any party to ensure support of this project. Any connectivity issues should be investigated with your authorized support representative.
To the extent permitted by applicable law.
GNU GENERAL PUBLIC LICENSE
Version 3, 29 June 2007
See LICENSE file for more information.
*/
const helperFunctions = require(`./helper-functions.js`);
module.exports = {
connectSMDR: (connectionType, smdrConnection, client, callback) => {
// Connect to PBX for SMDR
if(connectionType == `sv9500`){
helperFunctions.logMessage(`other`, `SMDR Client`, `Device set to: ` + smdrConnection.device);
helperFunctions.logMessage(`out`, `SMDR Client`, `Attempting to connect to ` + smdrConnection.ipAddress + `:` + smdrConnection.port + `...`);
client.connect(smdrConnection.port, smdrConnection.ipAddress, (err, response) => {
callback(response);
console.log(err || response);
});
}
},
sendSMDRRequest: (smdrConnection, client, callback) => {
// Checks for SMD records at PBX.
// Send SMDR_REQEST. Data Identifier 1 = Send billing data.
var smdrRequestBuffer = new Buffer.from([0x16, 0x31, 0x30, 0x30, 0x30, 0x30, 0x32, 0x30, `0x3` + smdrConnection.device, 0x06]);
// [Always 16, Identifier Kind, Data Length, Data Length, Data Length, Data Length , Data Length, Device Identifier , Device Identifier, Parity Byte]
//
// ,---------------- DATA ----------------,
client.write(smdrRequestBuffer);
callback(smdrRequestBuffer);
},
respondSMDR: (client, identifierKind, deviceNumber, sequenceNumber, callback) => {
if(identifierKind == `4`){
var identifierKind = `0x34`;
}
switch(deviceNumber) {
case `0`:
deviceNumber = `0x30`;
break;
case `1`:
deviceNumber = `0x31`;
break;
case `2`:
deviceNumber = `0x32`;
break;
case `3`:
deviceNumber = `0x33`;
break;
};
switch(sequenceNumber) {
case 0:
var parityByte = `0x36`;
sequenceNumber = `0x30`;
break;
case 1:
var parityByte = `0x37`;
sequenceNumber = `0x31`;
break;
case 2:
var parityByte = `0x34`;
sequenceNumber = `0x32`;
break;
case 3:
var parityByte = `0x35`;
sequenceNumber = `0x33`;
break;
case 4:
var parityByte = `0x32`;
sequenceNumber = `0x34`;
break;
case 5:
var parityByte = `0x33`;
sequenceNumber = `0x35`;
break;
case 6:
var parityByte = `0x30`;
sequenceNumber = `0x36`;
break;
case 7:
var parityByte = `0x31`;
sequenceNumber = `0x37`;
break;
case 8:
var parityByte = `0x3E`;
sequenceNumber = `0x38`;
break;
case 9:
var parityByte = `0x3F`;
sequenceNumber = `0x39`;
break;
default:
break;
};
var bufferArray = [0x16, identifierKind, 0x30, 0x30, 0x30, 0x30, 0x34, 0x30, deviceNumber, sequenceNumber , 0x06, parityByte]
var responseBuffer = new Buffer.from(bufferArray);
client.write(responseBuffer);
callback(responseBuffer);
},
sendStatusMonitor: (smdrConnection, client, callback) => {
// Send STATUS_MONITOR message to PBX. Data Identifier 5 = Heartbeat / Keep Alive.
// [Always 16, Identifier Kind, Data Length, Data Length, Data Length, Data Length , Data Length, Device Identifier , Device Identifier, 0x30 , 0x30 , 0x06, Parity Byte]
// ,-------------------------- DATA --------------------------,
// var statusMonitorBuffer = new Buffer.from([0x16, 0x35, 0x30, 0x30, 0x30, 0x30, 0x35, 0x30, `0x3` + smdrConnection.device, 0x30, 0x30, 0x06, 0xF9]);
switch(smdrConnection.device) {
case 0:
var parityByte = `0x06`;
var device = `0x30`;
break;
case 1:
var parityByte = `0x07`;
var device = `0x31`;
break;
case 2:
var parityByte = `0x34`;
sequenceNumber = `0x32`;
break;
case 3:
var parityByte = `0x35`;
sequenceNumber = `0x33`;
break;
};
var statusMonitorBuffer = new Buffer.from([0x16, 0x35, 0x30, 0x30, 0x30, 0x30, 0x35, 0x30, device, 0x30, 0x30, 0x06, 0x06]);
client.write(statusMonitorBuffer);
callback(statusMonitorBuffer);
},
sendDisconnectMessage: (smdrConnection, client) => {
var connectionDisconnectBuffer = new Buffer.from([0x16, 0x36, 0x30, 0x30, 0x30, 0x30, 0x33, 0x30, `0x3` + smdrConnection.device, 0x06, 0x06]);
console.log(`\n<= \n Connection Disconnect: `);
console.log(connectionDisconnectBuffer);
console.log(`<= \n`);
client.write(connectionDisconnectBuffer);
}
}