function [optimizer] = batCalcFunction(data,batEngMax,batEfficiency,EclipsePower,NominalPower,EPSefficiency,solarModifier)
%%%%%%Editable Variables%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%batEngMax=30; %%Watt Hours
%%batEfficiency=1;
%EclipsePower=5.5; %%WATTS
%NominalPower=7.6; %%WATTS
%EPSefficiency=0.95;
%SolarModifier=1;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
optimizer=0;
batEng=0;
output=zeros((length(data)),1); %%Blank Output array
minTimes=zeros(10,3); %%Listing energy states where we reached zero
x=1;
for q=1:length(data)
nomUsage=EPSefficiency*((NominalPower*data(q,2))+(EclipsePower*data(q,1)));
energy=solarModifier*data(q,4); %%find current orbits energy in
batEng=batEng*batEfficiency; %%Adjust Battery storage based on efficency
if((energy-nomUsage)>=0) %%if there is enough solar energy for nominal
if(batEng~=batEngMax) %%If there is energy left over add it to the batteries
batEng=batEng+(energy-nomUsage);
end
output(q)=2;
elseif(energy-nomUsage+batEng>=0) %%if solar energy + some bat can keep nominal on and if we prefer it
batEng=batEng-nomUsage+energy; %power the sat and subtract energy from battery
output(q)=1;
else %%If battery and solar cannot keep sat on
if(batEng~=batEngMax)
batEng=batEng+energy; %%add energy to the battery
end
output(q)=0; %%satellite goes dark
end
if(batEng>batEngMax)
batEng=batEngMax;
end
if(output(q)==0)
minTimes(x,1)=energy;
x=x+1;
%disp("Attempt Failed");
optimizer=optimizer+1;
end
end
%plot(output);
end