import argparse
import sys
import os
from aspLibs.aspUtilities import IntRange
from aspLibs.aspUtilities import V_HIGH
from aspLibs.aspUtilities import AspLogger
VOLT_LOW = 0
VOLT_HIGH = 1000
datatypespath = '\\DataTypes' # This is the subdirectory with the Lynx data structure definitions
parser = argparse.ArgumentParser(description='Program to turn on/off HV supply of Lynx',
formatter_class=argparse.ArgumentDefaultsHelpFormatter)
parser.add_argument('lynxIP', help='IP Number of Lynx.')
parser.add_argument('-s', '--status', help='Return status of Lynx HV settings and current value', action='store_true')
parser.add_argument('-o', '--on', help='Turn HV supply ON', action='store_true')
parser.add_argument('-f', '--off', help='Turn HV supply OFF', action='store_true')
parser.add_argument('-p', '--polarity', help='HV Polarity [(P)ositive or (N)egative]', type=str,
choices=['P', 'p', 'N', 'n'], default='N')
parser.add_argument('-v', '--voltage', help=f'HV Voltage value ({VOLT_LOW},{VOLT_HIGH})',
type=IntRange(VOLT_LOW, VOLT_HIGH))
parser.add_argument('-i', '--input', help='MCA input number. 0, 1, or 2', type=IntRange(0, 2), default=1)
# Read arguments passed on command line
args = parser.parse_args()
# Parse command line arguments
lynxIP = args.lynxIP
log = AspLogger(V_HIGH) # No real need for verbosity argument in this program, so echo everything
try:
# Setup the Python env
sys.path.append(os.getcwd() + datatypespath) # append DataTypes subdir to system path for Lynx library imports
from DeviceFactory import DeviceFactory
from ParameterCodes import ParameterCodes
mca_input = args.input
# Instantiate the device object
device = DeviceFactory.createInstance(DeviceFactory.DeviceInterface.IDevice)
# Open a connection to the device
device.open('', lynxIP)
# Get device name
dev_name = device.getParameter(ParameterCodes.Network_MachineName, 0)
# Gain ownership
# BARF on this hard-coded horror. However this will remain until Canberra responds with a reasonable way
# for us to take control as a user instead of always admin
device.lock('Administrator', 'Password', mca_input)
if args.voltage is not None:
log.disp(f'{dev_name}: Setting HV magnitude to {args.voltage}V')
device.setParameter(ParameterCodes.Input_Voltage, args.voltage, mca_input)
exit()
if args.polarity is not None:
if args.polarity.upper() == 'P':
log.disp('{dev_name}: Setting HV polarity to POSITIVE')
device.setParameter(ParameterCodes.Input_VoltagePolarity, False, mca_input)
else:
log.disp('{dev_name}: Setting HV polarity to NEGATIVE')
device.setParameter(ParameterCodes.Input_VoltagePolarity, True, mca_input)
if args.on:
log.disp(f'{dev_name}: Turning HV supply ON')
device.setParameter(ParameterCodes.Input_VoltageStatus, True, mca_input)
exit()
if args.off:
log.disp(f'{dev_name}: Turning HV supply OFF')
device.setParameter(ParameterCodes.Input_VoltageStatus, False, mca_input)
exit()
if args.status:
hv_set = device.getParameter(ParameterCodes.Input_Voltage, mca_input)
hv_read = round(device.getParameter(ParameterCodes.Input_VoltageReading, mca_input), 2)
if device.getParameter(ParameterCodes.Input_VoltagePolarity, mca_input): # Returns True if negative
hv_polarity = '-'
else:
hv_polarity = '+'
if device.getParameter(ParameterCodes.Input_VoltageStatus, mca_input):
hv_status = 'ON'
else:
hv_status = 'OFF'
log.disp(f'{dev_name}: HV Supply is {hv_status} and set to {hv_polarity}{hv_set}, reading back {hv_read}V')
exit()
except Exception as e:
# Handle any exceptions
print(f'Exception caught : {e}')