The Auto-Maskin DCU 210E firmware contains an...
Critical severity
Unreviewed
Published
May 13, 2022
to the GitHub Advisory Database
•
Updated Feb 1, 2023
Description
Published by the National Vulnerability Database
Oct 8, 2018
Published to the GitHub Advisory Database
May 13, 2022
Last updated
Feb 1, 2023
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
References