Sensor Update pattern cleanup #341
Annotations
10 errors and 11 warnings
build:
Source/Meadow.Foundation.Peripherals/Sensors.Moisture.Capacitive/Driver/Capacitive.cs#L12
'Capacitive' does not implement interface member 'IMoistureSensor.MoistureUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Distance.Hcsr04/Driver/Hcsr04.cs#L13
'Hcsr04' does not implement interface member 'IRangeFinder.DistanceUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Moisture.Fc28/Driver/Fc28.cs#L13
'Fc28' does not implement interface member 'IMoistureSensor.MoistureUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Distance.Vl53l0x/Driver/Vl53l0x.cs#L13
'Vl53l0x' does not implement interface member 'IRangeFinder.DistanceUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.LoadCell.Nau7802/Driver/Nau7802.cs#L13
'Nau7802' does not implement interface member 'IMassSensor.MassUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.LoadCell.Hx711/Driver/Hx711.cs#L13
'Hx711' does not implement interface member 'IMassSensor.MassUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Weather.WindVane/Driver/WindVane.cs#L21
'WindVane' does not implement interface member 'IWindVane.WindAzimuthUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Weather.SwitchingAnemometer/Driver/SwitchingAnemometer.cs#L15
'SwitchingAnemometer' does not implement interface member 'IAnemometer.WindSpeedUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Light.AnalogSolarIntensityGauge/Driver/AnalogSolarIntensityGauge.cs#L13
'AnalogSolarIntensityGauge' does not implement interface member 'ISolarIntensityGauge.SolarIntensityUpdated'
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Distance.MaxBotix/Driver/MaxBotix.cs#L11
'MaxBotix' does not implement interface member 'IRangeFinder.DistanceUpdated'
|
build
The following actions uses node12 which is deprecated and will be forced to run on node16: actions/setup-dotnet@v1. For more info: https://github.blog/changelog/2023-06-13-github-actions-all-actions-will-run-on-node16-instead-of-node12-by-default/
|
build:
Source/Meadow.Foundation.Core/Communications/ByteCommsSensorBase.cs#L72
Non-nullable property 'BusComms' must contain a non-null value when exiting constructor. Consider declaring the property as nullable.
|
build
'MqttClientDisconnectedEventArgs.ReasonCode' is obsolete: 'Please use 'Reason' instead. This property will be removed in the future!'
|
build
'MqttServerTlsTcpEndpointOptions.Certificate' is obsolete: 'Please use CertificateProvider with 'BlobCertificateProvider' instead.'
|
build
'MqttServerTlsTcpEndpointOptions.Certificate' is obsolete: 'Please use CertificateProvider with 'BlobCertificateProvider' instead.'
|
build
'MqttServerTlsTcpEndpointOptions.CertificateCredentials' is obsolete: 'Please use CertificateProvider with 'BlobCertificateProvider' including password property instead.'
|
build
'MqttNetGlobalLogger' is obsolete: 'Please pass an instance of the IMqttNetLogger to the factory/server or client. The global logger will be deleted in the future.'
|
build
'MqttNetGlobalLogger' is obsolete: 'Please pass an instance of the IMqttNetLogger to the factory/server or client. The global logger will be deleted in the future.'
|
build
This async method lacks 'await' operators and will run synchronously. Consider using the 'await' operator to await non-blocking API calls, or 'await Task.Run(...)' to do CPU-bound work on a background thread.
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Atmospheric.Si70xx/Driver/Si70xx.cs#L71
Non-nullable event '_temperatureHandlers' must contain a non-null value when exiting constructor. Consider declaring the event as nullable.
|
build:
Source/Meadow.Foundation.Peripherals/Sensors.Atmospheric.Si70xx/Driver/Si70xx.cs#L71
Non-nullable event '_humidityHandlers' must contain a non-null value when exiting constructor. Consider declaring the event as nullable.
|