Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsdp_i2c.h
248 lines (229 loc) · 10.2 KB
/
sdp_i2c.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
/*
* THIS FILE IS AUTOMATICALLY GENERATED
*
* I2C-Generator: 0.2.0
* Yaml Version: 0.1.0
* Template Version: 0.7.0-32-g5b8f0ff
*/
/*
* Copyright (c) 2021, Sensirion AG
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are met:
*
* * Redistributions of source code must retain the above copyright notice, this
* list of conditions and the following disclaimer.
*
* * Redistributions in binary form must reproduce the above copyright notice,
* this list of conditions and the following disclaimer in the documentation
* and/or other materials provided with the distribution.
*
* * Neither the name of Sensirion AG nor the names of its
* contributors may be used to endorse or promote products derived from
* this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
* AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*/
#ifndef SDP_I2C_H
#define SDP_I2C_H
#ifdef __cplusplus
extern "C" {
#endif
#include "sensirion_config.h"
#define SDP8XX_I2C_ADDRESS_0 0x25
#define SDP8XX_I2C_ADDRESS_1 0x26
#define SDP3X_I2C_ADDRESS_0 0x21
#define SDP3X_I2C_ADDRESS_1 0x22
#define SDP3X_I2C_ADDRESS_2 0x23
#define SDP_I2C_ADDRESS SDP8XX_I2C_ADDRESS_0
/**
* sdp_start_continuous_measurement_with_mass_flow_t_comp_and_averaging() - This
* command starts continuous measurements with mass flow temperature
* compensation and the average till read feature.
*
* @note The measurement command must only be sent once, if acknowledged. The
* command must not be resent or other commands must not be sent until the stop
* measurement command has been issued. After the start measurement command is
* sent, the first measurement result is available after 8ms. Small accuracy
* deviations (few % of reading) can occur during the next 12ms. The measured
* values are updated every 0.5ms and can be read using the read measurement
* interface.
*
* @return 0 on success, an error code otherwise
*/
int16_t
sdp_start_continuous_measurement_with_mass_flow_t_comp_and_averaging(void);
/**
* sdp_start_continuous_measurement_with_mass_flow_t_comp() - This command
* starts continuous measurements with mass flow temperature compensation.
*
* @note The measurement command must only be sent once, if acknowledged. The
* command must not be resent or other commands must not be sent until the stop
* measurement command has been issued. After the start measurement command is
* sent, the first measurement result is available after 8ms. Small accuracy
* deviations (few % of reading) can occur during the next 12ms. The measured
* values are updated every 0.5ms and can be read using the read measurement
* interface.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_start_continuous_measurement_with_mass_flow_t_comp(void);
/**
* sdp_start_continuous_measurement_with_diff_pressure_t_comp_and_averaging() -
* This command starts continuous measurements with differential pressure
* temperature compensation and the average till read feature.
*
* @note The measurement command must only be sent once, if acknowledged. The
* command must not be resent or other commands must not be sent until the stop
* measurement command has been issued. After the start measurement command is
* sent, the first measurement result is available after 8ms. Small accuracy
* deviations (few % of reading) can occur during the next 12ms. The measured
* values are updated every 0.5ms and can be read using the read measurement
* interface.
*
* @return 0 on success, an error code otherwise
*/
int16_t
sdp_start_continuous_measurement_with_diff_pressure_t_comp_and_averaging(void);
/**
* sdp_start_continuous_measurement_with_diff_pressure_t_comp() - This command
* starts continuous measurements with differential pressure temperature
* compensation.
*
* @note The measurement command must only be sent once, if acknowledged. The
* command must not be resent or other commands must not be sent until the stop
* measurement command has been issued. After the start measurement command is
* sent, the first measurement result is available after 8ms. Small accuracy
* deviations (few % of reading) can occur during the next 12ms. The measured
* values are updated every 0.5ms and can be read using the read measurement
* interface.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_start_continuous_measurement_with_diff_pressure_t_comp(void);
/**
* sdp_stop_continuous_measurement() - This command stops the continuous
* measurement and puts the sensor in idle mode. It powers off the heater and
* makes the sensor receptive to another command after 500us. The Stop command
* is also required when switching between different continuous measurement
* commands.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_stop_continuous_measurement(void);
/**
* sdp_trigger_measurement_with_mass_flow_t_comp_and_averaging() - This command
* triggers a single shot measurement with mass flow temperature compensation.
*
* @note During a triggered measurement the sensor measures both differential
* pressure and temperature. The measurement starts directly after the command
* has been sent. The command needs to be repeated with every measurement.
* During the 45ms that the sensor is measuring, no command can be sent to the
* sensor. After the 45ms the result can be read out and any command can be sent
* to the sensor.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_trigger_measurement_with_mass_flow_t_comp_and_averaging(void);
/**
* sdp_trigger_measurement_with_diff_pressure_t_comp() - This command triggers a
* single shot measurement with differential pressure temperature compensation.
*
* @note During a triggered measurement the sensor measures both differential
* pressure and temperature. The measurement starts directly after the command
* has been sent. The command needs to be repeated with every measurement.
* During the 45ms that the sensor is measuring, no command can be sent to the
* sensor. After the 45ms the result can be read out and any command can be sent
* to the sensor.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_trigger_measurement_with_diff_pressure_t_comp(void);
/**
* sdp_read_measurement() - After a start continuous measurement commands, the
* measurement results can be read out at most every 0.5ms. After a triggered
* measurement command, the results can be read out when the sensor is finished
* with the measurement. The temperature and scale factor don’t need to be read
* out (every time). The read sequence can be aborted by a NACK and a STOP
* condition. The scale factor is for differential pressure in Pascal.
*
* @param differential_pressure The digital calibrated differential pressure
* signal read from the sensor is a signed integer number (two's complement
* number). The integer value can be converted to the physical value by dividing
* it by the scale factor. differential pressure in Pascal = sensor output /
* scale factor
*
* @param temperature The digital calibrated temperature signal read from the
* sensor is a signed integer number (two's complement number). The integer
* value can be converted to the physical value by dividing it by a scale factor
* of 200. temperature in °C = sensor output / 200
*
* @param scaling_factor Scaling factor differential pressure
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_read_measurement(int16_t* differential_pressure,
int16_t* temperature, int16_t* scaling_factor);
/**
* sdp_enter_sleep_mode() - In sleep mode the sensor uses the minimum amount of
* current. The mode can only be entered from idle mode, i.e. when the sensor is
* not measuring. This mode is particularly useful for battery operated devices.
* To minimize the current in this mode, the complexity of the sleep mode
* circuit has been reduced as much as possible, which is mainly reflected by
* the way the sensor exits the sleep mode. In sleep mode the sensor cannot be
* soft reset.
*
* @note Triggered mode: the sleep command can be sent after the result have
* been read out and the sensor is in idle mode. Continuous mode: the sleep
* command can be sent after a stop continuous measurement command has been
* issued and the sensor is in idle mode.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_enter_sleep_mode(void);
/**
* sdp_exit_sleep_mode() - Exit sleep mode. See the data sheet for more detailed
* information
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_exit_sleep_mode(void);
/**
* sdp_prepare_product_identifier() - Prepare for reading the product identifier
* and sensor serial number.
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_prepare_product_identifier(void);
/**
* sdp_read_product_identifier() - Read the product identifier and serial number
* of the sensor.
*
* @note Make sure to call 'prepare product identifier' immediately before.
*
* @param product_number 32 bit unique product and revision number. The number
* is listed in the datasheet. Note that the last 8 bits are the revision number
* and can be subject to change.
*
* @param serial_number 64-bit unique serial number
*
* @return 0 on success, an error code otherwise
*/
int16_t sdp_read_product_identifier(uint32_t* product_number,
uint8_t* serial_number,
uint8_t serial_number_size);
#ifdef __cplusplus
}
#endif
#endif /* SDP_I2C_H */