Nuclear too flexible? #140

Open
GordStephen opened this issue Mar 19, 2022 · 2 comments
Open

Nuclear too flexible? #140

GordStephen opened this issue Mar 19, 2022 · 2 comments

Comments

@GordStephen
Copy link
Contributor

The nuclear unit ramp rate is given as 20 MW/min, about 5x higher than the comparably-sized gas CCs and coal units. Is that intentional?

@claytonpbarrows
Copy link
Member

not really, but the pmin is 396MW and pmax is 400, so while it may have really relaxed ramp rates, it can't go very far.

@claytonpbarrows
Copy link
Member

However, I would be happy to tighten them to something more realistic.