The nuclear unit ramp rate is given as 20 MW/min, about 5x higher than the comparably-sized gas CCs and coal units. Is that intentional?
The text was updated successfully, but these errors were encountered:
not really, but the pmin is 396MW and pmax is 400, so while it may have really relaxed ramp rates, it can't go very far.
Sorry, something went wrong.
However, I would be happy to tighten them to something more realistic.