Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmain.py
125 lines (94 loc) · 3.24 KB
/
main.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
import sys
from enerctl import *
def usage():
print("""COMMAND [OPTION]...
Send COMMAND to a legacy Energenie 433 MHz radio controlled wall socket.
Commands:
cmd SEQUENCE Send a custom 4-bit binary code to the socket
off [SOCKET] Turn SOCKET off
on [SOCKET] Turn SOCKET on
Miscellaneous:
h, help Display this help message
q, quit Exit the console
Omitting the socket number means on/off commands will be accepted by all
sockets within range of the transmitter.
Examples:
on
cmd 1001
off 3""")
def cleanup():
transmitter_cleanup()
gpio_cleanup()
def main():
gpio_init()
transmitter_init()
try:
while True:
cmd = input("> ")
cmd = [item.lower() for item in cmd.split()]
if not cmd:
continue
elif ("help" in cmd) or ("h" in cmd):
usage()
continue
base_cmd = cmd.pop(0)
if base_cmd == "cmd":
if not cmd:
print("ERROR: Control sequence required")
continue
elif len(cmd) > 1:
print("ERROR: Too many arguments")
continue
code_str = cmd.pop(0)
if len(code_str) != 4:
print("ERROR: Invalid control sequence")
continue
try:
code = int(code_str, 2)
except ValueError:
print("ERROR: Invalid control sequence")
continue
k_0 = (code >> 0) & 1
k_1 = (code >> 1) & 1
k_2 = (code >> 2) & 1
k_3 = (code >> 3) & 1
send_code(k_3, k_2, k_1, k_0)
print(f"Control code {code_str} transmitted")
continue
elif base_cmd == "quit":
cleanup()
sys.exit(0)
# Default socket ID is 5 (for all)
sock_id = ALL_SOCKETS
if cmd:
try:
sock_id = int(cmd.pop(0))
except ValueError:
print("ERROR: Invalid socket ID")
continue
if cmd:
print("ERROR: Too many arguments")
continue
if sock_id != ALL_SOCKETS:
if not MINIMUM_SOCKET_ID <= sock_id <= MAXIMUM_SOCKET_ID:
print(f"ERROR: Socket ID ({sock_id}) out of range. Must be {MINIMUM_SOCKET_ID}-{MAXIMUM_SOCKET_ID}")
continue
if base_cmd == "off":
socket_off(sock_id)
if sock_id == ALL_SOCKETS:
print("All sockets powered off")
else:
print(f"Socket {sock_id} powered off")
elif base_cmd == "on":
socket_on(sock_id)
if sock_id == ALL_SOCKETS:
print("All sockets powered on")
else:
print(f"Socket {sock_id} powered on")
else:
print(f"ERROR: {base_cmd} is an invalid command")
except KeyboardInterrupt:
print("")
cleanup()
if __name__ == "__main__":